Using Certified Reference Materials (CRM) daily gives quick and easy insight into the performance of the methods.

Use Certified Reference Materials (CRM) in your Quality Control Program for:
• Daily process control
• Performance testing of culture media according to ISO 11133
• Performance testing of membrane filters according to ISO 7704
• Interlaboratory comparison studies
• Validation and verification studies

CRM for water analyses meets the standards ISO 17025 and NPR 6268.

CRMStrainWDCMStandard (examples)
CRM-AHY.00063BLAeromonas hydrophila00063NEN 6263
CRM-CFR.00006BLCitrobacter freundii00006ISO 9308-1
RAPID’E.coli 2 for Water Testing
Petrifilm Enterobacteriaceae (PFEB)
CRM-CPE.00007BLClostridium perfringens00007ISO 14189
ISO 6461
CRM-ECO.00013BLEscherichia coli00013ISO 6222
ISO 9308-1
RAPID’E.coli 2 for Water Testing
Petrifilm Aqua Heterotrophic Count Plates (AQHC)
Petrifilm Enterobacteriaceae (PFEB)
CRM-ECO.00012BHEscherichia coli00012ISO 9308-1
RAPID’E.coli 2 for Water Testing
Petrifilm Enterobacteriaceae (PFEB)
CRM-EFA.00009BLEnterococcus faecalis00009ISO 7899-2
RAPID’Enterococcus for Water Testing
COMPASS ENTEROCOCCUS AGAR
CRM-EFA.00178BLEnterococcus faecium00178ISO 7899-2
CRM-LAN.00106BLLegionella anisa00106ISO 11731
CRM-LPN.BHLegionella pneumophila100617aISO 11731
CRM-LPN.00107BLLegionella pneumophila00107ISO 11731
CRM-PAE.00024MLPseudomonas aeruginosa00024ISO 16266
RAPID’P.aeruginosa for Water Testing
CRM-SAU.00034BLStaphylococcus aureus00034NF T 90-412
CRM-AQUAColony Count Water:
Escherichia coli
Enterococcus faecalis
Pseudomonas fluorescens
Total count/dead count Flow cytometry

00013
00087
100423a
ISO 6222
ISO 9308-1
ISO 13720
ISO 7899-2
RAPID’E.coli 2 for Water Testing
ISO 19344
Petrifilm Aqua Heterotrophic Count Plates (AQHC)
Petrifilm Enterobacteriaceae (PFEB)
CRM-COFAEscherichia coli
Enterococcus faecium
00179
00178
ISO 9308-1
RAPID’E.coli 2 for Water Testing
ISO 7899-2
RAPID’Enterococcus for Water Testing
COMPASS ENTEROCOCCUS AGAR

a NCCB number

If your desired CRM is not listed, please contact us at info@biosisto.com for an alternative or request a tailor-made CRM.

 

 

 

 

We will respond to your message by email as soon as possible.
Comments specificly relevant for this article and other visitors will be published in this section. Questions that also apply to other articles are published in the F.A.Q. section.

Comment on this article

Your email address will not be published. Required fields are marked *

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.



Biosisto - Quality in Control

Microbiological laboratories should be able to receive reliable analysis without much overhead. A microbiological analyst must be able to focus on the primary activities, for example analysis of the sample material. Quality control should support the analyst in a logical and simple manner. By using modern information technology, process control and quality assurance are designed smarter and more effective.

Biosisto b.v.
Martin Luther Kingweg 3
9403 PA Assen, The Netherlands
www.biosisto.com

BiosistoStandard